mobileMenu


Dynamic imaging of tracer transport in beadpacks and Ketton Limestone by Positron Emission Tomography (PET)

Dataset title Dynamic imaging of tracer transport in beadpacks and Ketton Limestone by Positron Emission Tomography (PET)
Dataset creators Takeshi Kurotori, Qatar Carbonates and Carbon Storage Research Centre, Department of Chemical Engineering, Imperial College London
Principal investigator: Dr Ronny Pini, Qatar Carbonates and Carbon Storage Research Centre, Department of Chemical Engineering, Imperial College London.
Dataset theme Geoscientific Information
Dataset abstract

The data contains three-dimensional maps of the temporal and spatial distribution of tracer concentration during miscible displacements with aqueous solutions in two cylindrical porous samples, thus including beadpack (BP) and Ketton Limestone (KL). The dynamic imaging of the displacement process was conducted using two different PET scanners, namely a Siemens Biograph 64 PET/CT for the experiments with the BP (at Imanova Ltd, UK) and a Siemens INVEON DPET for the experiments with KL (at Stanford University, USA). The experiments were carried out at flow rates, q = 10 mL/min for BP and q = 4 mL/min for KL. Each PET image represents an average over a constant time frame (45 frames of 20 seconds each for BP and 40 frames of 60 seconds each for KL). For BP, each 3D tomogram includes (128 x 128 x 111) voxels with size (1.34 x 1.34 x 2) mm3. For KL, each 3D tomogram includes (128 x 128 x 159) voxels with size (0.78 x 0.78 x 0.8) mm3. The PET dataset was used in Kurotori et al. (2018)* to characterise mm-scale dispersion during miscible displacements in these two porous media. The experimental observations of the spatio-temporal evolution of the tracer plume can also be used as a benchmark test for different numerical models for solute transport in heterogeneous porous media. Further details on the use of the PET images can be found in Kurotori et al. (2018).

*T. Kurotori, C. Zahasky, S. A. Hosseinzadeh Hejazi, S.M. Shah, S.M. Benson, Measuring, imaging and modelling solute transport in a microporous limestone, Chemical Engineering Science (2018), under review.

Dataset content dates 17/06/2016 - 29/09/2017
Dataset spatial coverage Not Applicable
Dataset supply format DICOM files (.dcm) , IMG file (.img)
Dataset language English-United Kingdom
Dataset discovery metadata record Discovery Link to the dataset's BGS Discovery Metadata record
Dataset publisher British Geological Survey
Dataset publication date 6th October 2018
Dataset digital object identifier(DOI) 10.5285/bac5a5ed-caaa-49e2-845b-9f4a561fd909
Dataset citation text Takeshi Kurotori (2018): Dynamic imaging of tracer transport in beadpacks and Ketton Limestone by Positron Emission Tomography (PET). British Geological Survey. (Dataset). http://dx.doi.org/10.5285/bac5a5ed-caaa-49e2-845b-9f4a561fd909
Constraints and terms of use This data set is delivered under the terms of the Open Government Licence, subject to the following acknowledgement accompanying any reproduced materials: "Imperial College London gratefully acknowledge permission to publish and funding from the Qatar Carbonates and Carbon Storage Research Centre (QCCSRC), provided jointly by Qatar Petroleum, Shell, and Qatar Science & Technology Park. Qatar Petroleum remain copyright owner."
Access the dataset https://www.bgs.ac.uk/services/ngdc/accessions/index.html#item120009